Warning: strtotime() [function.strtotime]: It is not safe to rely on the system's timezone settings. You are *required* to use the date.timezone setting or the date_default_timezone_set() function. In case you used any of those methods and you are still getting this warning, you most likely misspelled the timezone identifier. We selected 'Asia/Krasnoyarsk' for 'WIB/7.0/no DST' instead in /home/acrpanel/public_html/panel/libraries/joomla/utilities/date.php on line 56

Warning: strtotime() [function.strtotime]: It is not safe to rely on the system's timezone settings. You are *required* to use the date.timezone setting or the date_default_timezone_set() function. In case you used any of those methods and you are still getting this warning, you most likely misspelled the timezone identifier. We selected 'Asia/Krasnoyarsk' for 'WIB/7.0/no DST' instead in /home/acrpanel/public_html/panel/libraries/joomla/utilities/date.php on line 56

Warning: date() [function.date]: It is not safe to rely on the system's timezone settings. You are *required* to use the date.timezone setting or the date_default_timezone_set() function. In case you used any of those methods and you are still getting this warning, you most likely misspelled the timezone identifier. We selected 'Asia/Krasnoyarsk' for 'WIB/7.0/no DST' instead in /home/acrpanel/public_html/panel/libraries/joomla/utilities/date.php on line 198

Warning: date() [function.date]: It is not safe to rely on the system's timezone settings. You are *required* to use the date.timezone setting or the date_default_timezone_set() function. In case you used any of those methods and you are still getting this warning, you most likely misspelled the timezone identifier. We selected 'Asia/Krasnoyarsk' for 'WIB/7.0/no DST' instead in /home/acrpanel/public_html/panel/libraries/joomla/utilities/date.php on line 198
PDF Print E-mail

Our machine is consist of different model, depend on customer needs


Type A

  • Electronic control instrument.
  • Expansion device: capillary tube.
  • Liquid line filter (molecular sieve type).
  • Room lighting on all units.
  • Cable for door heater connection on low temperature units.
  • Three-phase units and several model are provided with fixed calibration
  • high pressure switch. This outfit complies with the provisions of the
  • “Pressure Equipment Directive” 97/23/EC.
  • Condensate evaporation tray and safety overflow drain on all units.
  • Drain heater on all medium and low temperature units.
  • Wall-mounted, straddle-type units.
  • Units recommended for use at ambient temperatures not lower than
  • 10°C. In case of outdoor installation it is necessary to protect them from
  • the weather.

Optional

  • Special voltage.
  • Water-cooled condenser: units equipped with water-cooled condenser
    are also provided with a pressure controlled water valve, a fixed
    calibration high pressure switch (even on single-phase units),
    as well as a compressor cooling fan (low temperature units only).
  • Voltage monitor.
  • High pressure switch
  • Condenser fan pressure switch
  • Condenser fan speed regulator
  • Switchboard heater
  • Crankcase heater
  • Supplemental solenoid valve (on the discharge line of medium and
    low temp. units, recommended in case they are exposed to low ambient
    temperatures).

 


 

Type B

  • Electronic control instrument.
  • Expansion device: capillary tube.
  • Liquid line filter (molecular sieve type).
  • Room lighting on all units.
  • Cable for door heater connection on low temperature units.
  • Three-phase units and several model are provided with a fixed calibration
  • high pressure switch. This outfit complies with the provisions of the
  • “Pressure Equipment Directive” 97/23/EC.
  • Condensate evaporation tray and safety overflow drain on all units.
  • Drain heater on all medium and low temperature units.
  • Through-the-wall installation.
  • Units recommended for use at ambient temperatures not lower than
  • 10°C. In case of outdoor installation it is necessary to protect them from
  • the weather.

Optional

  • Special voltage.
  • Water-cooled condenser: units equipped with water-cooled condenser
    are also provided with a pressure controlled water valve, a fixed
    calibration high pressure switch (even on single-phase units),
    as well as a compressor cooling fan (low temperature units only).
  • Remote panel : already connected to the unit and provided with a 5
    meters long cable (on request extension up to 20 meters).
  • Voltage monitor.
  • High pressure switch
  • Condenser fan pressure switch
  • Condenser fan speed regulator
  • Switchboard heater
  • Crankcase heater
  • Supplemental solenoid valve (on the discharge line of medium and
    low temp. units, recommended in case they are exposed to low ambient
    temperatures).

 


 

 

 

 

Type C

  • Electronic control instrument.
  • Expansion device: capillary tube.
  • Solid core filter on the Liquid line.
  • Room lighting on all units.
  • Cable for door switch connection; door switch functions can be programmed
    on the electronic control panel.
  • Cable for door heater connection on low temperature units.
  • All units are equipped with a fixed calibration low pressure switch; all
    three-phase units are also provided with a fixed
    calibration high pressure switch. This outfit complies with the provisions
    of the «Pressure Equipment Directive» 97/23/EC.
  • Remote panel: already connected to the unit and provided with a 5
    meters long cable (on request extension up to 20 meters).
  • Direct drainage of condensate.
  • Roof-mounted units.
  • Units recommended for use at ambient temperatures not lower than
    10°C. Suitable accessories are required for use at temperatures
    below 10°C. In case of outdoor installation it is necessary to protect
    them from the weather.

 

Optional

  • Special voltage.
  • Water-cooled condenser: units equipped with water-cooled condenser
    are also provided with a pressure controlled water valve, a fixed
    calibration high pressure switch (even on single-phase units),
    as well as a compressor cooling fan (low temperature units only).
  • Voltage monitor.
  • High pressure switch (only for voltage 230/1/50, except for several model).
  • Condenser fan pressure switch.
  • Switchboard heater.
  • Crankcase heater.
  • Supplemental solenoid valve (on the discharge line of both
    medium and low temp. units, recommended in case they are exposed to
    low ambient temperatures).

 

 

 

 

 


 


 

AC&R GROUP. ACR PANEL - Jalan raya legok KM.6 Legok-Tangerang 15820- Indonesia

Tel. (+62-21).54200088, 54201370, 54201367 - Fax. (+62-21) 54203111

ACR The perfect solution for your refrigerator needs